New Submissions Are Not Currently Being Accepted
Samples sent after April 10, 2024 will be put on hold.
Viewing desktop version: Switch to Mobile
M30
Sold as: Oxycontin
ID: 12476
Result Photo Detail Photo Detail Photo
GC/MS Graph
Detail Photo
ID: 12476
Name: M30
Other Names:
UniqueCode:More infoUnique Lookup Code is an alphanumeric string created by the submitter and included with the sample so anonymously submitted samples can be positively identified as the submitter's sample. LJT27
Marquis:More infoThe Marquis Test is a reagent field test conducted by placing a drop of reagent liquid onto a small sample of the material being tested. The chemicals in the reagent react differently with different chemicals, turning a variety of colors based on the what is in the material being tested. Light Brown
Mecke:More infoAs with the Marquis Test, The Mecke Test is a reagent field test conducted by placing a drop of liquid reagent onto a sample of the material in question. Mecke reagent is primarily used for the identification of heroin and other opiates. No Reaction
Mandelin:More infoThe Mandelin Test is a reagent field test conducted by placing a drop of liquid reagent onto a sample of the material in question. Mandelin is primarily used for the detection of ketamine and PMA. It is a mixture of ammonium metavanadate and concentrated sulfuric acid. No Reaction
GC/MS:More infoThe GC/MS Lab Test  
Test Date: Mar 24, 2022
Pub. Date: Mar 24, 2022
Src Location: Queens, NY
Submitter Loc: Brooklyn, NY
United States
Color: Blue
Size: 112 mg, 6.56 mm x 3.04 mm
Data Source: DrugsData
Tested by: DDL
Lab's ID: 22030048
Sold as: Oxycontin
Expected to be: Not Sure
Has Been Tried: No
Sugars / Diluents Detected
The lab identified sugars or diluents in this sample: Mannitol

Round blue tablet with 'M' on one side, '30' and break line on the other. Counterfeit oxycodone. Sample name given as 'Roxy'.
Mar 29 2022: The previously unidentified substance is likely N-(4-fluorophenyl)-N-(1-propionylpiperidin-4-yl)propionamide [the 'propionyl' fluoro-norfentanyl], which has no CAS# at this time. There doesn't appear to be a certified reference standard for this, and this identification is unlikely to be confirmed until there is.

This substance was originally identified in sample #11464 through the Erowid Expert Network.